Model | MPS204 | MPS304 | MPS404 |
Rated Voltage | 96VDC | ||
Rated charge current | 20A | 30A | 40A |
Load current | 15A | ||
Input voltage range | 100-188VDC | ||
Max PV open circuit array voltage | 188VDC | ||
Typical idle consumption | At idle < 10mA | ||
Overload protection (DC load) | 2.0*Inom>5s 1.5*Inom>20s 1.25*Inom temperature controlled |
||
Bulk charge | 116.8V(default) | ||
Floating charge | 107.2V(default) | ||
Equalization charge | 112V(default) | ||
Overcharge disconnection | 118.4V | ||
Over charge recovery | 108.8V | ||
Over discharge disconnection | 86.4V(default) | ||
Over discharge reconnection | 98.4V | ||
Temperature compensation | -26.4mV/ºC | ||
Lead acid battery settings | Adjustable | ||
NiCad battery setting | Adjustable | ||
Load control mode | 1. Low Voltage Reconnect(LVR): Adjustable 2. Low Voltage Disconnect(LVD): Automatic disconnection 3. Reconnection: Includes warning flash before disconnect and reconnection |
||
Low voltage reconnect | 96.0-112.0Vdc | ||
Low voltage disconnect | 84.0-100.0Vdc | ||
Ambient temperature | 0-40ºC(full load) 40-60ºC(de-rating) | ||
Altitude | Operating 5000m, Non-Operating 16000m | ||
Protection class | IP21 | ||
Battery temperature sensor | BTS- optional remote battery temperature sensor for increased charging precision | ||
Terminal size(fine/single wire) | #8 AWG |